The AUTO PRO series have been developed in consideration of various demands of customers. Semifinished products (units) by the lot production are completed by adding functions according to the user specifications. Therefore, any models can be delivered quickly as long as the system is structured with the standard units. Various optional units are also available to provide the customers with the specific functions they require.


Features
Precision/stability
・  High analysis precision and stability can be obtained by the use of a high throughput CPU. (Average error: ±3%)
High speed analysis
・  The analysis time can be reduced by the high-speed and high torque metering pumps.
(The analysis of the concentrations of alkali, copper, and formalin, and pH of electroless copper plating bath can be done at a minimum speed of 15 minutes.).
Easy operation
・  The operation is very easy and can be done without referring to the instruction manual.
Easy maintenance
・  Devices are so positioned that all the maintenance operations may be carried out in the front of the system.
Applicability in overseas
・  Using the dedicated transformer, it can be used at different voltages in the major cities of the world
Extendability
・  The concentration signal generated by the system can be used as the control signal of other devices.

AUTO PRO Cute series
One system can analyze up to 4 basic components.
Four external signals can be outputted for each analysis item.
  [Extreme upper limit/Upper limit/Lower limit (supply)/Extreme lower limit]
Supply methods may be selected from among many options.
 [The timer control or the pulse control. The proportional supply or the proportional cumulative supply.]
Samples are taken directly from the bath.

AUTO PRO Light series block diagram


Applicable processes of the AUTO PRO Cute series
Model Process Items of analysis
 SA
 Acidic-/ electro-cleaning
(1) Free acid, including acid concentration
 SH
 Degreasing
(1) Free alkali, including NaOH
 ZC/A
 Zincate A
(1)NaOH (2)Zn2+
 ZC/B
 Zincate B
(1)NaOH (2)H2CO3 (3)Zn2+
 EL-Cu/PTH
Electroless Cu plating
(1)NaOH (2)HCHO (3)Cu2+ (4)pH
 EL-Ni/P
 Electroless Ni plating for industrial use
(1)pH (2)Ni2+
 EL-Ni/A
 Electroless Ni plating for plastics
(1)pH (2)Ni2+
 A-66
 Accelerator
(1)PC-66H
 MAB
 Reduction (weak acid)
(1) MAB-4B (acid)  (2) MAB-4B (reducing agent)
 N-PC
 Neutralization reduction
(1)H2SO4 (2)H2O2 (3)Cu2+
 M-SPS
 Microetching
(1)H2SO4  (2) SPS (persulfate)  (3)Cu2+
 PB-300
 Catalyzing
(1)Pd2+ (2)Cu2+
 HS
 Solder plating
(1) Organic acid (2)Sn2+
 Cu/CN
 Copper cyanide plating
(1)NaOH (2)CN- (3)Cu2+
 Ag/CN
 Silver cyanide plating
(1)NaOH (2)CN-
 DG1
 Desmearing/degreasing
(1) Alkalinity (2)Cu2+
 ET1
 Desmearing/PI etching
(1) Alkalinity  (2) Permanganic acid (3) Manganic acid
 RD1
  Desmearing/neutralization reduction
(1)pH (2) DS-310 (Reducing agent)
 DG2
 DPS microetching
(1) Alkalinity (2) Concentration of copper impurities
 MC1
 DPS microetching
(1) Persulfate (2) Sulfuric acid((3) Concentration of copper impurities
 AC1
 DPS activator
(1)Pd2+ (2)Sn2+ (3) Concentration of copper impurities
 MT1
 DPS metallizer
(1) pH (2) Alkalinity  (3) Copper concentration
 SB1
 DPS stabilizer
(1) Acid concentration (2) Concentration of copper impurities
Note: Before use, a preliminary test of the system with the actual process to be analyzed should be performed to ensure the performance. Model names are subject to change.

Up to 5 supply pumps can be installed.
* We can investigate the plating processes and analysis items that are not on the above list. Please consult us.


AUTO PRO Light series
One system can analyze up to 2 basic components.
A single external signal can be outputted for each analysis item.
  [Lower limit (supply)]
Supply can be done as an option.
  [Constant amount of supply by the timer control]
Samples are taken directly from the bath.

AUTO PRO Light series block diagram


Applicable processes of the AUTO PRO Light series
Model
Process
Items of analysis
 LPH
 Baths that require pH control, including the electroless Ni plating bath
Continuous pH measurement
 LNI
 Ni control of electroless Ni plating bath
Continuous Ni measurement
 LSA
 Pre-treatment bath, etching bath
 Composition control of the dry film bath for PWBs
Acid and alkali concentrations based on neutralization titration
 LCU
 Copper concentration control of soft etching and electroless copper plating baths
Copper
 LHC
 Formalin concentration control of electroless copper plating bath
Formalin
 LH2
 Concentration control of hydrogen peroxide for etching bath
Hydrogen peroxide solution
 LME
 Concentration control of metallic iimpurities for zincate
 and neutralization baths
Metal ions
 LZC
 Concentration control of the zincate bath
(1)NaOH (2)Zn2+
* Model names are subject to change.
* Other analysis items may be added from time to time.
Note: Before use, a preliminary test of the system with the actual process to be analyzed should be performed to ensure the performance.

Up to 2 supply pumps can be installed.
* We can investigate the plating processes and analysis items that are not on the above list